Lead-Acid Battery Charge Discharge Test System

Item No.: DK-RM48
Input Power: AC200V~245V50/60HZ
Applicable Batteries: 6V/8V/12V/16V/18V Lead-acid batteries
Charge Con-Voltage: 7V-23V
Discharge Cut-off Voltage: 2V-20V
Discharge Current: 0.5A-20A
Charge Current: 0.5A-10A
Operation Method: Panel
Description
DK-RM48 is a large-scale battery test system integrated with charge & discharge, auto-cycle test, it can set the voltage and current of charge and discharge by the user, and has automatic charging and discharging cycle function, the max. cycle number is up to 50 times. The instrument provides 7 work modes for easy operation. The equipment is widely used in battery production, battery recycling and other industries that require large-scale battery testing. 

DK exclusive charge and discharge module can be flexibly configured in the test system, the maximum discharge current can up to 50A, and the maximum charge current can up to 30A. 

Battery Charge Discharge Testing System



Applicable Batteries:
6V/8V/12V/16V/18V Lead-acid batteries, recommended capacity:<65 AH.


Features:
- Each channel is equipped with a dedicated processor to ensure a perfect level of capacity calculation, timing, voltage and current control.
- Instrument displays by LCD, each index is clear at a glance.
- The parameter setup and parameter switching are set and switched by a “START” switch and a “SET” knob. All parameters(voltage, current, mode) setting have the saving function.
- Intelligent speed fan can run continuously, delay the power-off of the fan, and blow-off the remaining heat.
- Polarity protection, anti-reverse connection, and so on.
- Each circuit is the independent module, no influence each other
- The instrument have simple mode and professional mode for choice to meet the different requirement of the user.
- Data protection startup: If the connection cables disconnected from the battery during the charging and discharging, after reconnecting the cables with the battery, press and hold the “Start” button to continue working.
- Power-off memory function.

- DK exclusive charge and discharge module can be flexibly configured in the test system, the maximum discharge current can up to 50A, and the maximum charge current can up to 30A.

Operation Modes:

7 Work Modes
Mode Code Descriptions
0 Query mode of historical loop data
1 Capacity discharging test
2 Typical charge
3 Loop mode 3: Starting with discharge and ending with charge
                       Max. loop number: 50 times
4 Loop mode 4: Starting with charge and ending with charge
                       Max. loop number: 50 times
5 Loop mode 5: Starting with discharge and ending with discharge
                       Max. loop number: 50 times
6 Loop mode 6: Starting with charge and ending with discharge
                       Max. loop number: 50 times


Technical Specification:
Model No.: DK-RM48
Items Parameter
Input Voltage: AC 220 V± 10% 50 Hz / 60 Hz
Input Power:
 
No-load: 0.48KW
Full-load: 9.60KW
Channel Number: 48
Applicable Battery Types: 6 V, 12 V, 16 V, 18V Storage Batteries
Functions:
 
 
 
Charge
Discharge
 
Auto cycle charge and discharge
Data record and inquire
Voltage
 
 
 
 
 
 
 
Max. Charge Voltage: 23 V
Min. Charge Voltage: 7V
Amplitude Of Adjustment: 0.1 V stepping
Charge Voltage Tolerance: ± 0.5 V
Max. Discharge Cut-off Voltage: 20 V
Min. Discharge Cut-off Voltage: 2 V
Amplitude Of Adjustment: 0.1 V stepping
Discharge Voltage Tolerance: ± 0.03 V
Current
 
 
 
 
 
Charge Current: 0.5 A – 10 A adjustable
Amplitude Of Adjustment: 0.1 A stepping
Charge Current Tolerance: ± 0.1 A
Discharge Current: 0.5 A – 20 A adjustable
Amplitude Of Adjustment: 0.1 A stepping
Discharge Current Tolerance: ± 0.03 A
Charge
 
Charge Mode: Constant current & voltage charge
Cut-off Conditions: When reaching high constant voltage, the system will automatically switch to trickle charge after charging for 3.5 hours or the charging current is less than 0.3A
Discharge
 
Discharge Mode: Constant current discharge
Cut-off Conditions: Voltage
Cycle Max. Cycle Index: 50 Times
Protection:
 
 
 
 
Power-down protection
Reverse connection protection
Over-temperature protection
Over-voltage protection
Short-circuit protection
IP Grade IP20
Channel Control Mode Independent control
High Voltage Insulation Between Channels AC1000V/2min Normal
Data Display LCD
Operation Method Panel
Voltage & Current Test Sampling Four-core wires connection
Noise < 76 dB
Upper Computer Communication None
Communication Port None
Equipment Work Ambient Conditions
Operation Ambient Temperature 0 ℃ - 40 ℃
Storage Temperature -10 ℃ - 50 ℃
Operation Ambient Humidity ≤ 70 % RH (No condensation)
Storage Ambient Humidity ≤ 80 % RH (No condensation)



Illustrations





LCD Interface



Production Size: 
216(L)*40(W)*181(H) cm

Application:



 